class B+C, I+II surge protector 3 poles
Item No: FV30B+C/3-xxx(S)
-Clss B+C/I+II Surge protector onsisting of 3 base part and MOV plug-in protection modules.
-High energy MOV inside.
-Low residual voltage and quick response.
-Reliable control thanks to Thermo Dynamic Control disconnector.
-With remote signaling contact for control device.
-Fault indication via red mark in the inspection window.
-Protection mode: L1, L2, L3-PE, N-PE.
-High energy MOV inside.
-Low residual voltage and quick response.
-Reliable control thanks to Thermo Dynamic Control disconnector.
-With remote signaling contact for control device.
-Fault indication via red mark in the inspection window.
-Protection mode: L1, L2, L3-PE, N-PE.
Product Description
1.Coding system
2.Dimension and circuit of 3 poles classB+C surge protector FV30B+C/3-xxx S
FV30B+C/3-150S, FV30B+C/3-275S, FV30B+C/3-320S
FV30B+C/3-385S, FV30B+C/3-440S
3.Electrical parameters of 3 poles classB+C surge protector FV30B+C/3-xxx S
4.Installation of 3 poles classB+C surge protector FV30B+C/3-xxx S
5. TUV-mark, TUV-CE certificates
Please contact us directly by phone or email sales@fatech-surge-protection.com for asking origin certificates file.
2.Dimension and circuit of 3 poles classB+C surge protector FV30B+C/3-xxx S
FV30B+C/3-150S, FV30B+C/3-275S, FV30B+C/3-320S
FV30B+C/3-385S, FV30B+C/3-440S
3.Electrical parameters of 3 poles classB+C surge protector FV30B+C/3-xxx S
Model No. | FV30B+C/3- 150(S) |
FV30B+C/3- 275(S) |
FV30B+C/3- 320(S) |
FV30B+C/3- 385(S) |
FV30B+C/3- 440S) |
||
Rated Voltage | UN | VAC | 110/220 | 230/400 | 230/400 | 230/400 | 230/400 |
Max. continuous. operating voltage | UC | VAC | 150 | 275 | 320 | 385 | 440 |
Nominal discharge current(8/20μs) | In | kA | 30 | 30 | 30 | 30 | 30 |
Max. discharge current (8/20μs) | Imax | kA | 60 | 60 | 60 | 60 | 60 |
Iimpulse discharge current (10/350μs) | Iimp | kA | 7 | 7 | 7 | 7 | 7 |
Voltage protection level (at In) | Up | kV | ≤0.9 | ≤1.5 | ≤1.8 | ≤2.0 | ≤2.2 |
Response time | tA | ns | <25 | <25 | <25 | <25 | <25 |
Recommended back-up fuse | A | 160 | 160 | 160 | 160 | 160 | |
I/O Connections | By screw terminal:10-35mm2; By connection bus | ||||||
Mounting | Symmetrical rail(EN50022/DIN46277-3) | ||||||
Operation temperature range | -40℃~+85℃ | ||||||
Degree of protection | IP20 | ||||||
Housing material | UL94V0 | ||||||
Disconnection indicator | Mechanical indicator | ||||||
Remote control contact | Optional |
4.Installation of 3 poles classB+C surge protector FV30B+C/3-xxx S
5. TUV-mark, TUV-CE certificates
Please contact us directly by phone or email sales@fatech-surge-protection.com for asking origin certificates file.