International Standard on Lightning and Surge Protection
Standard IEC / TC 64、TC 77、TC 85、TC 81
Item
|
Standard No.
|
Name
|
Remark
|
1
|
IEC 60364-4-443:1990
|
Electrical installations of buildings- Part 4: Protection for safety Chapter 44: Protection against overvoltages Section 443– Protection against overvoltages of atmospheric origin or due to switching
|
|
2
|
IEC 60364-5-534:1997
|
Electrical installations of buildings- Part 5: Selection and erection of electrical equipment – Section 534: Devices for protection against overvoltages
|
|
3
|
IEC 60664-1:1992
|
Insulation coordination for equipment within low-voltage systems- part 1: Principles, requirements and tests
|
|
4
|
IEC 60664-1 AMD 1:1992
|
Insulation coordination for equipment within low-voltage systems- part 1: Principles, requirements and tests (Amendment 1)
|
|
5
|
IEC 61200-52:1993
|
Electrical installation guide – Part 52:Selection and erection of electrical equipment – Wiring systems
|
|
6
|
IEC 61000-4-5:1995
|
Electromagnetic compatibility (EMC) – Part 4: Testing and measurement techniques – Section 5: Surge immunity test
|
|
7
|
IEC 61000-4-5 AMD 1:2000
|
Electromagnetic compatibility (EMC) – Part 4: Testing and measurement techniques – Section 5: Surge immunity test
(Amendment 1)
|
|
8
|
IEC 61557-4:1997
|
Electrical safety in low voltage distribution systems up to 1000V a.c.and1500V d .c. -Equipment for testing, measuring or monitoring of protective measures-Part 4: Resistance of earth connection and equipotential bonding
|
|
Standard IEC / TC 81
Item
|
Standard No.
|
Name
|
Remark
|
1
|
IEC 61024-1:1990
|
Protection of structures against lighting-Part 1:General principles
|
|
2
|
IEC 61024-1-1:1993
|
Protection of structures against lighting-Part 1:General principles Section 1: Guide A: Selection of protection levels for lightning protection systems
|
|
3
|
IEC 61024-1-2:1998
|
Protection of structures against lighting-Part 1-2: General principles Guide B: Design, installation, maintenance and inspection of lightning protection systems
|
|
4
|
IEC 61312-1:1995
|
雷击电磁脉冲的防护 第1部分:通则
Protection against lightning electromagnetic impulse-Part 1:General principles
|
|
5
|
IEC 61312-2:1999
|
Protection against lightning electromagnetic impulse (LEMP)- Part 2: Shielding of structures, bonding inside structures and earthing
|
|
6
|
IEC 61312-3:2000
|
Protection against lightning electromagnetic impulse-Part 3: Requirements of surge protective devices (SPDs)
|
|
7
|
IEC 61312-4:1998
|
Protection against lightning electromagnetic impulse-Part 4: Protection of equipment in existing structures
|
|
8
|
IEC 61662:1995
|
Assessment of the risk of damage due to lightning
|
|
9
|
IEC 61662 AMD1:1996
|
Assessment of the risk of damage due to lightning (Amendment 1)
|
|
10
|
IEC 61663-1:1999
|
Lightning protection-Telecommunication lines-Part 1:Fibre optic installations
|
|
11
|
IEC 61663-2/Ed.1:2001
|
Protection contre la foudre-Lignes de telecommunication-Partie 2: Lignes utilisant des conducteurs metalliques
|
|