Surge Protective Device FV30C/1 S
Item No: FV30C/1-xxx S
-Class II / Type 2 surge protective devices.
-Consisting of a base part and1 MOV plug-in protection modules.
-For using in the lightning protection zones concept at boundary 1-2.
-The core parts are metal oxide vristor components with high discharge capacity.
-Low residual voltage and quick response
-Reliable control thanks to Thermo Dynamic Control disconnector.
-With remote signaling contact for control device.
-Fault indication via red mark in the inspection window.
-Protection mode: L/N-PE.
-Consisting of a base part and1 MOV plug-in protection modules.
-For using in the lightning protection zones concept at boundary 1-2.
-The core parts are metal oxide vristor components with high discharge capacity.
-Low residual voltage and quick response
-Reliable control thanks to Thermo Dynamic Control disconnector.
-With remote signaling contact for control device.
-Fault indication via red mark in the inspection window.
-Protection mode: L/N-PE.
Product Description
1.Coding system
2.Dimension and circuit of 60KA surge protective device FV30C/1-xxx S
3.Electrical parameters of 60KA surge protective device FV30C/1-xxx S
Hot Tags:surge protective device, surge protective device manufacturer,China surge protective device,
surge protective device supplier, 60kA surge protective device
4.Installation of 60KA surge protective device FV30C/1-xxx S
2.Dimension and circuit of 60KA surge protective device FV30C/1-xxx S
3.Electrical parameters of 60KA surge protective device FV30C/1-xxx S
Model No. | FV30C/1-150S | FV30C/1-275S | FV30C/1-320S | ||||
Rated Voltage | UN | VAC | 110/220 | 230/400 | 230/400 | ||
Max. continuous. operating voltage | UC | VAC | 150 | 275 | 320 | ||
Nominal discharge current(8/20μs) | In | kA | 30 | 30 | 30 | ||
Max. discharge current (8/20μs) | Imax | kA | 60 | 60 | 60 | ||
Voltage protection level (at In) | Up | kV | ≤0.9 | ≤1.5 | ≤1.8 | ||
Response time | tA | ns | <25 | <25 | <25 | ||
Recommended back-up fuse | A | 125 | 125 | 125 | |||
Protection mode | L/N-PE | ||||||
I/O Connections | By screw terminal:10-35mm2; By connection bus | ||||||
Mounting | Symmetrical rail(EN50022/DIN46277-3) | ||||||
Operation temperature range | -40℃~+85℃ | ||||||
Degree of protection | IP20 | ||||||
Housing material | UL94V0 | ||||||
Disconnection indicator | Mechanical indicator (Green: ok, Red: replace) | ||||||
Remote control contact | Optional |